Outside Plant

The outside plant includes substantial network capability distributed between two wirecenters. Each exhibit hall is one wircenter and contains central infrastructure as well as distribution cabling. The wirecenters are linked in a centra/remote architecture, with the remote being fed by 1 T1 circuit and a 1000BaseSX circuit.

Using the advanced capabilities of the Shady Rate Interface, some exhibitor circuits "loop through" other customer premises. These circuits are on existing trunk infrastructure, but are not present on the interface equipment at these customer sites.

Wirecenter - TRNTY

The TRNTY wirecenter services the main hall and immediately adjacent spaces such as show registration.

Central Office

Name: Petar's Place

Table: 97,98,99,100

Service:

  • 1:1 - Analog POTS (x7013)
  • 1:2 - Analog POTS (x7014)

Name: IBM RT PC

Table: 146,147,148

Service:

  • 2:1 - Analog POTS (x7004)
  • 2:2 - Analog POTS (x7005)

Name: Forgotten Machines

Table: 130,131,132,133,149

Service:

  • 2:3 - Analog POTS (x7002)
  • 2:4 - Analog POTS (x7003)

Name: Donut's Hole in the Wall

Table: 136

Service:

  • 3:1 - Analog POTS (x7011)
  • 3:2 - Analog POTS (x7012)

Name: Alex and Will

Table: 138,139,140,141,142,143,144

Service:

  • 3:3 - Analog POTS (x7006)
  • 3:4 - Analog POTS (x7007)

Name: TechAV

Table: 17

Service:

  • 4:1 - Analog POTS (x7000)

Name: Midrange UNIX Machines

Table: 19,20

Service:

  • 4:2 - Analog POTS (x7001)

Name: It's Alive

Table: 26

Service:

  • 5:1 - Analog POTS (x7008)
  • 5:2/3 - TDM PRI

Name: IBM 3270 Terminals

Table: 102

Service:

  • 6:1 - Analog POTS (x7015)
  • 6:2/3 - TDM PRI

Name: Adventures in Vintage Computing

Table: 33

Service:

  • 7:1 - Analog POTS (x7009)
  • 7:2 - Analog POTS (x7010)

Name: Meddling Nerds

Table: 35,36

Service:

  • 7:3 - Analog POTS (x7016)
  • 7:4 - Analog POTS (x7017)

Name: Phone Zoo (Bank 1)

Table: CO

Service:

  • 8:1 - Analog POTS (x7030)
  • 8:2 - Analog POTS (x7031)
  • 8:3 - Analog POTS (x7032)
  • 8:4 - Analog POTS (x7033)

Name: Phone Zoo (Bank 2)

Table: CO

Service:

  • 9:1 - Analog POTS (x7034)
  • 9:2 - Analog POTS (x7035)
  • 9:3 - Analog POTS (x7036)
  • 9:4 - Analog POTS (x7037)

Wirecenter: OAK

Service:

  • T1 - Customer INTERNAL
Trunk 1 (50 feet)Trunk 2 (65 feet)Trunk 2 (50 feet)Trunk 3 (75 feet)Trunk 3 (50 feet)Trunk 4 (75 feet)Trunk 4 (50 feet)Trunk 5 (75 feet)Trunk 6 (30 feet)Trunk 7 (100 feet)Trunk 7 (50 feet)Trunk 8 (20 feet)Trunk 9 (20 feet)Trunk 10 (300 feet)

Wirecenter - OAK

The OAK wirecenter is a rural market with very few customers.

Central Office

Oak Channel Bank

Fed From CO

Name: Mark Romberg

Table: 225

Service:

  • 1:1 - Analog POTS (x7048)
Trunk 1 (75 feet)